Product Details
- Accommodates 3/4" (19mm) latch projection
- 1-1/2" (38mm) cut-out depth accommodates most door frame material types
- Use with wide range of door thicknesses, 1-3/8" to 2-3/8" (35mm-60mm)
- Standard mounting tabs and fasteners included
- Non-handed
- Trim plate included to cover up irregular frame cutout
- 200mA 11-16VAC, 12VAC/VDC, 24VAC/VDC (At 12VDC)
- 1,500lbf Static2 70ft-lb Dynamic (1,500lbf Static for fire-rated models, 1,000lbf for non-fire-rated 04 & 14 faceplates, 500lbf for 05, 07, 08 & 19 faceplates.)
- 500,000 Cycles (Fire-rated (F) models only, 250,000 for other models)
- Fail-Secure & Fail-Safe
- Optional 1-1/2-Hour Models Available (Fire-rated (F) models only available in fail-secure mode with 04 & 14 faceplates)
- 3 Year Limited Warranty
Technical Details
Insert Depth: 1-1/2"D (38mm)
- Brushed Stainless Steel (32D) finish
- UL 1034 burglary-resistant Listed
- UL 10C, 1-1/2-hour fire-rating Listed (Fire-rated (F) models only available in fail-secure mode with 04 & 14 faceplates.)
- CAN/ULC S104, 1-1/2-hour fire-rating Listed (Fire-rated (F) models only available in fail-secure mode with 04 & 14 faceplates.)
- Certified to ANSI/BHMA standard A156.31, Grade 1, endurance 500,000 cycles (Fire-rated (F) models only, 250,000 for other models)
Components
Accessories
- 4/7JIG - Standard profile frame prep jig, aluminum
- LEK01 - 1" lip extension kit for retrofit applications, black finish (not available for F4 fire-rated series)
- LEK02 - 2" lip extension kit for retrofit applications, black finish (not available for F4 fire-rated series)
- LEK03 - 3" lip extension kit for retrofit applications, black finish (not available for F4 fire-rated series)
- SMT-01 - Strike marketing template kit, aluminum
- TP-47-5PK - Trim plates, 5 pack, black finish
- 930-LG - Standard profile latch guard, 32D finish
Applications
- Commercial Centers
- Industrial Buildings
- Educational Facilities
- Retail Outlets
- Health Care Facilities
- Office Complexes



Product Downloads
F4 Series Installation Manual - ISF4
126.21 KB
1.12.2018
Installation instructions for the RCI F4 series electric strikes
ICEPK Installation Manual - ISICEPK
133.92 KB
1.11.2019
Installation instructions for the RCI ICEPK (ice pack)
4 & 7 Series Installation Manual - IS47A
342.24 KB
1.03.2019
Installation instructions for the RCI 4/7 series electric strikes
4, 6, & 7 Series Lip Bracket Extension Install Manual - ISLE
302.05 KB
1.07.2021
Installation instructions for the RCI electric strike lip bracket extensions for 4,6,7 series electric strikes
4 & 7 Series Frame Prep Installation Manual - IS47JIG
60.86 KB
1.11.2018
Frame prep JIG instructions for RCI 4 and 7 series electric strikes
Can’t find what you’re looking for?